PCA Reference Data and Services
Toggle Dark/Light/Auto modeToggle Dark/Light/Auto modeToggle Dark/Light/Auto mode

Ready for operation (RFO) close out report

A class with identifier http://rds.posccaesar.org/ontology/plm/rdl/PCA_100006409

MetadataThis section provides information about 'PCA_100006409' itself.

Source ontologynorsok-z001
CommentAll records and documents produced as a result of the monitoring and control requirements and the acceptance criteria shall, on completion of the work, be compiled into a Closeout Report.

The Closeout Report shall be divided into sections as follows: Section 1 This section shall give an introduction, general description of the system made ready for operation, list the chemicals used and describe the purpose of - and the structure of the Closeout Report. Section 2 This section shall contain the reports from the RFO operations. It shall contain summaries of events for all the operations and associated field operational paperwork. Section 3 This section shall contain all the operational procedures and field queries (FQs) for the operations associated with the RFO operations. Section 4 This section shall contain the RFO Contractors daily reports generated at the different sites where activities have been performed. These reports shall contain the day-by-day activities, , an environmental report listing the volumes of chemicals on site and a radioactive isotope form, listing the amount of isotopes in the field.

NORSOK Z-001 rationaleA close out report shall be delivered to document the work performed.
NORSOK Z-001 interests stakeholder categorypipeline engineering
NORSOK Z-001 describes structural elementFacility
NORSOK Z-001 definitionAll records and documents produced as a result of the monitoring and control requirements and the acceptance criteria shall, on completion of the work, be compiled into a Closeout Report.

The Closeout Report shall be divided into sections as follows: Section 1 This section shall give an introduction, general description of the system made ready for operation, list the chemicals used and describe the purpose of - and the structure of the Closeout Report. Section 2 This section shall contain the reports from the RFO operations. It shall contain summaries of events for all the operations and associated field operational paperwork. Section 3 This section shall contain all the operational procedures and field queries (FQs) for the operations associated with the RFO operations. Section 4 This section shall contain the RFO Contractors daily reports generated at the different sites where activities have been performed. These reports shall contain the day-by-day activities, , an environmental report listing the volumes of chemicals on site and a radioactive isotope form, listing the amount of isotopes in the field.

skos:broaderReport

ConstraintsThis section lists constraints that members of 'PCA_100006409' shall satisfy.

ContextThis section provides super- and subtypes as well as members of 'PCA_100006409'.