Supplier calculations
A class with identifier
http://rds.posccaesar.org/ontology/plm/rdl/PCA_100006473
Source ontology | norsok-z001 |
Comment | Characteristics and functional parameters shall be documented and performance shall be shown to be probable. This shall include but not be limited to calculations, curves, tables, reference to similar applications and test data. This shall as a minimum be at a level customary for the equipment and to the extent such data are of importance for interfaces to plant and system. Lateral analyses and torsion analyses for compressors performance curves for pumps and compressors. Strength calculations, thermal performance and vibration calculations for heat exchangers/pressure vessels. |
NORSOK Z-001 rationale | Can be input to system calculation and engineering |
NORSOK Z-001 describes structural element | Equipment |
NORSOK Z-001 definition | Characteristics and functional parameters shall be documented and performance shall be shown to be probable. This shall include but not be limited to calculations, curves, tables, reference to similar applications and test data. This shall as a minimum be at a level customary for the equipment and to the extent such data are of importance for interfaces to plant and system. Lateral analyses and torsion analyses for compressors performance curves for pumps and compressors. Strength calculations, thermal performance and vibration calculations for heat exchangers/pressure vessels. |
skos:broadMatch | explanatory technical information |
skos:broader | Calculation |