Utility consumption report

A class with identifier http://rds.posccaesar.org/ontology/plm/rdl/PCA_100006518

MetadataThis section provides information about 'PCA_100006518' itself.

Source ontologynorsok-z001
CommentFor all utility systems the following shall be included in the utility consumption report: - For the total system: - Total system capacity (duty, flow rate and/or other parameter relevant for capacity); - Maximum coincident consumer load (duty, flow rate and/or other parameter relevant for capacity); - Description of utility characteristic/quality prior to distribution to consumers (pressure, temperature, composition and/or other relevant parameters); - Storage capacity; - For the consumers: - Tag number; - Continuous or intermittent consumer; - Required consumption, both maximum, normal and minimum consumption; - Description of utility characteristic/quality at consumer.
NORSOK Z-001 rationaleInput to procurement and multi-discipline design. Information to operation regarding utility system design.
NORSOK Z-001 interests stakeholder categoryprocess engineering
NORSOK Z-001 describes structural elementSteam
Lubrication oil
Closed drain
Sea water
Fire water
Flare
Jet fuel
Heating medium
Fuel gas
Sewage treatment
Chlorination
Compressed air
Fresh water
Fire fighting
Cooling medium
Hydraulic power
Chemical injection
Drilling drain
Oily water
Open drain
Thruster and propulsion
Diesel oil
Methanol injection
Ballast water
Inert gas
NORSOK Z-001 definitionFor all utility systems the following shall be included in the utility consumption report: - For the total system: - Total system capacity (duty, flow rate and/or other parameter relevant for capacity); - Maximum coincident consumer load (duty, flow rate and/or other parameter relevant for capacity); - Description of utility characteristic/quality prior to distribution to consumers (pressure, temperature, composition and/or other relevant parameters); - Storage capacity; - For the consumers: - Tag number; - Continuous or intermittent consumer; - Required consumption, both maximum, normal and minimum consumption; - Description of utility characteristic/quality at consumer.
skos:broadMatchexplanatory technical information
skos:broaderReport

ConstraintsThis section lists constraints that members of 'PCA_100006518' shall satisfy.

ContextThis section provides super- and subtypes as well as members of 'PCA_100006518'.