PCA Reference Data and Services
Toggle Dark/Light/Auto modeToggle Dark/Light/Auto modeToggle Dark/Light/Auto mode

Valve and operator test reports

A class with identifier http://rds.posccaesar.org/ontology/plm/rdl/PCA_100006521

MetadataThis section provides information about 'PCA_100006521' itself.

Source ontologynorsok-z001
CommentThe following test reports are required: 1. Fugitive emission test reports when specified by Purchaser 2. Test reports from qualification of non-collapsible choke valves when specified by Purchaser 3. For intelligent positioner with 4-20 mA input and HART or Fieldbus communication and diagnostic possibilities, a documented footprint/valve signature from FAT shall be delivered in a file with ZIP format (containing the data in native format) in addition to PDF. 4. FAT reports 5. FAT reports for actuators according to TR0038 Valve and operator test reports shall be delivered in PDF format with the addition described above for the intelligent positioner.
NORSOK Z-001 interests stakeholder categoryquality management
NORSOK Z-001 definitionThe following test reports are required: 1. Fugitive emission test reports when specified by Purchaser 2. Test reports from qualification of non-collapsible choke valves when specified by Purchaser 3. For intelligent positioner with 4-20 mA input and HART or Fieldbus communication and diagnostic possibilities, a documented footprint/valve signature from FAT shall be delivered in a file with ZIP format (containing the data in native format) in addition to PDF. 4. FAT reports 5. FAT reports for actuators according to TR0038 Valve and operator test reports shall be delivered in PDF format with the addition described above for the intelligent positioner.
skos:broadMatchvalidation and verification information
skos:broaderReport

ConstraintsThis section lists constraints that members of 'PCA_100006521' shall satisfy.

ContextThis section provides super- and subtypes as well as members of 'PCA_100006521'.