Buildings architectural drawings

A class with identifier http://rds.posccaesar.org/ontology/plm/rdl/PCA_100006110

MetadataThis section provides information about 'PCA_100006110' itself.

Source ontology norsok-z001
Comment Architectural layout drawings (plans, elevations) and cross sections and details of all architectural components shall be produced.nnDrawings showing extent and details for thermal and acoustic insulation and fire protection shall be included. All penetrations including windows and doors shall be shown.nnLocation, direction and type of signpost shall be shown on architectural layout drawings.nnThe drawing scale for architectural layout drawings shall normally be 1:100 in A3 format. However different scales can be used on A1 format if readable when reduced to A3 format. The drawings shall include stairs, walls, doors, windows, furniture, access and escape routes and all tagged equipment.nnMain dimensions shall be included. Elevations of all floors and platforms etc. shall be shown. A key plan, grid lines with north and east references and match lines with drawing references shall be included. Relevant civil, structural, HVAC, etc. drawings be referenced. The drawings shall have a title block which contains all the information necessary to identify the drawing and its purpose.
NORSOK Z-001 interests stakeholder category architectural engineering
NORSOK Z-001 describes structural element Location
NORSOK Z-001 definition Architectural layout drawings (plans, elevations) and cross sections and details of all architectural components shall be produced.nnDrawings showing extent and details for thermal and acoustic insulation and fire protection shall be included. All penetrations including windows and doors shall be shown.nnLocation, direction and type of signpost shall be shown on architectural layout drawings.nnThe drawing scale for architectural layout drawings shall normally be 1:100 in A3 format. However different scales can be used on A1 format if readable when reduced to A3 format. The drawings shall include stairs, walls, doors, windows, furniture, access and escape routes and all tagged equipment.nnMain dimensions shall be included. Elevations of all floors and platforms etc. shall be shown. A key plan, grid lines with north and east references and match lines with drawing references shall be included. Relevant civil, structural, HVAC, etc. drawings be referenced. The drawings shall have a title block which contains all the information necessary to identify the drawing and its purpose.
skos:broadMatch in/on-equipment location information
skos:broader Drawing

ConstraintsThis section lists constraints that members of 'PCA_100006110' shall satisfy.

ContextThis section provides super- and subtypes as well as members of 'PCA_100006110'.