General arrangement drawing

A class with identifier http://rds.posccaesar.org/ontology/plm/rdl/PCA_100006233

MetadataThis section provides information about 'PCA_100006233' itself.

Source ontology norsok-z001
Comment Below are examples of expected level of detail. One or more examples may apply.nFor Mechanical equipment:n - Dimensionsn - Location and identification of piping and main componentsn - Necessary space for disassembly and maintenancen - Location of centre of gravityn - Thermal expansion effect, when relevantn - On the structural steel drawings, critical welds shall be included with a weld nidentification number serving as a cross-reference to the weld summary indexn - Obstacles from other disciplines shall be included when relevantn - Total weight, wet and dry and in operational conditionn - Weights, centre of gravity and main dimensions of disassembled units/components nover 25 kg. Lifting lugs and runway beam for disassembling and their location shall nbe shownn - Identification and location of all nozzle and external pipe connections as well as nrequirements for flexible connections and acceptable loads and moments. Locations nshall be dimensioned and tolerances shown, if necessary in separate drawingsn - Identification and location of all external electrical and control monitoring connections n(may be given in separate drawings describing the electrical arrangement and ninstrumentation)n - For pressure equipment: for projects at locations where EU regulations for pressure nequipment apply, Category and Module shall be according to 2014/68/EU (PED)n - Include bolt tension requirements for pressure equipment flangesn - Iidentification of lubrication pointsn - Foundation information shall include:n - The outer dimensions and footprint of the support frame or foundation supportsn - The size, grade and location of the foundation bolts and torque where this is nnecessaryn - Forces and moments transferred to load bearing structures, both under normal noperation and extreme conditionsn - Details for adjustment and alignmentn - Details for cut-outs inside outer limit of foundationn - Details for vibration dampening units (if installed)nnFor Electrical equipment:n - Panel equipment layout - position of modules, cards, vacant slots and other ninformation necessary for expansion or installation of new equipment in the same ncabinetn - Internal layout showing arrangement of auxiliary modules, cable trunks, etc.n - All equipment including junction boxes, push buttons, light fittings, socket outlets, etc.n - Dimensionsn - Necessary space for disassembly and maintenancen - Location of centre of gravityn - Possible thermal expansionn - Obstacles from other disciplines shall be included when relevantnnFor Instrument equipment:n - Dimensionsn - Location and identification of piping and main componentsn - Necessary space for disassembly and maintenancen - Location of centre of gravityn - Possible thermal expansionn - Obstacles from other disciplines shall be included when relevantn - Panel equipment layout - position of modules, cards, vacant slots and other ninformation necessary for expansion or installation of new equipment in the same ncabinetn - Internal/back layout showing arrangement of auxiliary modules, cable trunks, etc.n - All equipment including technical network cabinets, junction boxes, push buttons, nlight fittings, socket outlets, etc.n - Reference to part list/SPIRnnFor Telecom equipment:nA detailed drawing of the equipment shall be delivered. The drawing shall be to scale with ndimensions included.nFor Panel/cabinet/rack the following shall be included in addition:n - Position of modules, cards, vacant slots and other information necessary for nexpansion or installation of new equipment in the same cabinet/rackn - Internal/back layout showing arrangement of auxiliary modules, cable trunks, etc.nnFor HVAC equipment:n - Dimensionsn - Location and identification of piping, ducting, MCTs (Multi core transit) and main ncomponentsn - Necessary space for disassembly and maintenancen - Location of centre of gravityn - Possible thermal expansionn - Obstacles from other disciplines shall be included when relevantnFoundation information shall include:n - The outer dimensions and footprint of the support frame or foundation supportsn - The size, grade and location of the foundation bolts and torque where this is nnecessaryn - Forces and moments transferred to load bearing structures, both under normal noperation and extreme conditionsn - Details for adjustment and alignmentn - Details for cut-outs inside outer limit of foundationn - Details for vibration dampening units (if installed)nnFor Lifting appliances:nGeneral arrangement drawing of complete unit and foundation:n - Dimensionsn - Location of centre of gravityn - Total weight in operational conditionnFoundation:n - The outer dimensions and footprint of the support frame or foundation nsupportn - The size, grade and location of the foundation bolts and torque where this is nnecessaryn - Forces and moments transferred to load bearing structures, both under nnormal operation and extreme conditionsn - Details for adjustment and alignmentnGeneral arrangement drawing for Crane cabin, machinery room, winches, crane boom, nslewing drives, main drive, hook block, wire sheave arrangements, etc.:n - Dimensionsn - Location and identification of bolting, piping and main componentsn - Location of centre of gravityn - Total weight in operational conditionnGeneral arrangement drawing for inspections for primary steel structures e.g. npedestal/foundation, crane boom/traverse beams, A-frame, runway beams, winches, hook nblock, etc.n - Critical welds shall be included with a weld identification number including weldnclassification. NDT procedures and intervals for each weld classification shall be nincluded.nnFor Well completion equipment:nElectrical submergible pump (ESP)n - Dimensionsn - Weights, centre of gravity and main dimensions of disassembled nunits/components over 25 kgnWellhead penetratorn - Dimensionsn - Necessary space for disassembly and maintenancen - Obstacles from other disciplines shall be included when relevantn - All equipment including technical network cabinets, junction boxes, push buttons, nlight fittings, socket outlets, etc.n - Parts list
NORSOK Z-001 rationale The manufacturer's standard general arrangement drawing shall be delivered. The content of the GA drawing must be adapted to the item described.
NORSOK Z-001 definition Below are examples of expected level of detail. One or more examples may apply.nFor Mechanical equipment:n - Dimensionsn - Location and identification of piping and main componentsn - Necessary space for disassembly and maintenancen - Location of centre of gravityn - Thermal expansion effect, when relevantn - On the structural steel drawings, critical welds shall be included with a weld nidentification number serving as a cross-reference to the weld summary indexn - Obstacles from other disciplines shall be included when relevantn - Total weight, wet and dry and in operational conditionn - Weights, centre of gravity and main dimensions of disassembled units/components nover 25 kg. Lifting lugs and runway beam for disassembling and their location shall nbe shownn - Identification and location of all nozzle and external pipe connections as well as nrequirements for flexible connections and acceptable loads and moments. Locations nshall be dimensioned and tolerances shown, if necessary in separate drawingsn - Identification and location of all external electrical and control monitoring connections n(may be given in separate drawings describing the electrical arrangement and ninstrumentation)n - For pressure equipment: for projects at locations where EU regulations for pressure nequipment apply, Category and Module shall be according to 2014/68/EU (PED)n - Include bolt tension requirements for pressure equipment flangesn - Iidentification of lubrication pointsn - Foundation information shall include:n - The outer dimensions and footprint of the support frame or foundation supportsn - The size, grade and location of the foundation bolts and torque where this is nnecessaryn - Forces and moments transferred to load bearing structures, both under normal noperation and extreme conditionsn - Details for adjustment and alignmentn - Details for cut-outs inside outer limit of foundationn - Details for vibration dampening units (if installed)nnFor Electrical equipment:n - Panel equipment layout - position of modules, cards, vacant slots and other ninformation necessary for expansion or installation of new equipment in the same ncabinetn - Internal layout showing arrangement of auxiliary modules, cable trunks, etc.n - All equipment including junction boxes, push buttons, light fittings, socket outlets, etc.n - Dimensionsn - Necessary space for disassembly and maintenancen - Location of centre of gravityn - Possible thermal expansionn - Obstacles from other disciplines shall be included when relevantnnFor Instrument equipment:n - Dimensionsn - Location and identification of piping and main componentsn - Necessary space for disassembly and maintenancen - Location of centre of gravityn - Possible thermal expansionn - Obstacles from other disciplines shall be included when relevantn - Panel equipment layout - position of modules, cards, vacant slots and other ninformation necessary for expansion or installation of new equipment in the same ncabinetn - Internal/back layout showing arrangement of auxiliary modules, cable trunks, etc.n - All equipment including technical network cabinets, junction boxes, push buttons, nlight fittings, socket outlets, etc.n - Reference to part list/SPIRnnFor Telecom equipment:nA detailed drawing of the equipment shall be delivered. The drawing shall be to scale with ndimensions included.nFor Panel/cabinet/rack the following shall be included in addition:n - Position of modules, cards, vacant slots and other information necessary for nexpansion or installation of new equipment in the same cabinet/rackn - Internal/back layout showing arrangement of auxiliary modules, cable trunks, etc.nnFor HVAC equipment:n - Dimensionsn - Location and identification of piping, ducting, MCTs (Multi core transit) and main ncomponentsn - Necessary space for disassembly and maintenancen - Location of centre of gravityn - Possible thermal expansionn - Obstacles from other disciplines shall be included when relevantnFoundation information shall include:n - The outer dimensions and footprint of the support frame or foundation supportsn - The size, grade and location of the foundation bolts and torque where this is nnecessaryn - Forces and moments transferred to load bearing structures, both under normal noperation and extreme conditionsn - Details for adjustment and alignmentn - Details for cut-outs inside outer limit of foundationn - Details for vibration dampening units (if installed)nnFor Lifting appliances:nGeneral arrangement drawing of complete unit and foundation:n - Dimensionsn - Location of centre of gravityn - Total weight in operational conditionnFoundation:n - The outer dimensions and footprint of the support frame or foundation nsupportn - The size, grade and location of the foundation bolts and torque where this is nnecessaryn - Forces and moments transferred to load bearing structures, both under nnormal operation and extreme conditionsn - Details for adjustment and alignmentnGeneral arrangement drawing for Crane cabin, machinery room, winches, crane boom, nslewing drives, main drive, hook block, wire sheave arrangements, etc.:n - Dimensionsn - Location and identification of bolting, piping and main componentsn - Location of centre of gravityn - Total weight in operational conditionnGeneral arrangement drawing for inspections for primary steel structures e.g. npedestal/foundation, crane boom/traverse beams, A-frame, runway beams, winches, hook nblock, etc.n - Critical welds shall be included with a weld identification number including weldnclassification. NDT procedures and intervals for each weld classification shall be nincluded.nnFor Well completion equipment:nElectrical submergible pump (ESP)n - Dimensionsn - Weights, centre of gravity and main dimensions of disassembled nunits/components over 25 kgnWellhead penetratorn - Dimensionsn - Necessary space for disassembly and maintenancen - Obstacles from other disciplines shall be included when relevantn - All equipment including technical network cabinets, junction boxes, push buttons, nlight fittings, socket outlets, etc.n - Parts list
skos:broadMatch on-site location information
in/on-equipment location information
skos:broader Arrangement Drawing

ConstraintsThis section lists constraints that members of 'PCA_100006233' shall satisfy.