General arrangement drawings - Pipeline structures

A class with identifier http://rds.posccaesar.org/ontology/plm/rdl/PCA_100006240

MetadataThis section provides information about 'PCA_100006240' itself.

Source ontology norsok-z001
Comment These drawings shall contain the following information:n - Dimensionsn - Location and identification of piping and main componentsn - Necessary space for disassembly and maintenancen - Location of centre of gravityn - Possible thermal expansion.n - On the structural steel drawings, critical welds shall be included with a weld identification number serving as a cross-reference to the weld summary indexn - Obstacles from other disciplines shall be included when relevantn - Total weight, wet and dry and in operational conditionn - Weights, centre of gravity and main dimensions of disassembled units/components over 25 kg. Lifting lugs and runway beam for disassembling and their location shall be shownn - Identification and location of all external pipeline connections as well as requirements for flexible connections and acceptable loads and moments. Locations shall be dimensioned, and tolerances shown, if necessary, in separate drawingsn - Identification and location of all external electrical and control monitoring connections (may be given in separate drawings describing the electrical arrangement and instrumentation)n - For pressure equipment: For projects within the EU, Category and Module shall be according to PED (Pressure equipment directive)n - Include bolt tension requirements for pressure equipment flangesn - identification of lubrication pointsnnFoundation information (such as support frame, support structure) shall include:n - The outer dimensions and footprint of the support frame or foundation supportsn - The size, grade and location of the foundation bolts and torque where this is necessaryn - Forces and moments transferred to load bearing structures, both under normal operation and extreme conditionsn - Details for adjustment and alignmentn - Details for cut-outs inside outer limit of foundationn - Details for vibration dampening units (if installed)
NORSOK Z-001 rationale General arrangement drawings for pipeline structures such as riser bases, pipeline protection structures, tee/wye assemblies, anchor blocks, valve stations, pump stations, pig traps etc.
NORSOK Z-001 interests stakeholder category pipeline engineering
NORSOK Z-001 describes structural element Equipment
NORSOK Z-001 definition These drawings shall contain the following information:n - Dimensionsn - Location and identification of piping and main componentsn - Necessary space for disassembly and maintenancen - Location of centre of gravityn - Possible thermal expansion.n - On the structural steel drawings, critical welds shall be included with a weld identification number serving as a cross-reference to the weld summary indexn - Obstacles from other disciplines shall be included when relevantn - Total weight, wet and dry and in operational conditionn - Weights, centre of gravity and main dimensions of disassembled units/components over 25 kg. Lifting lugs and runway beam for disassembling and their location shall be shownn - Identification and location of all external pipeline connections as well as requirements for flexible connections and acceptable loads and moments. Locations shall be dimensioned, and tolerances shown, if necessary, in separate drawingsn - Identification and location of all external electrical and control monitoring connections (may be given in separate drawings describing the electrical arrangement and instrumentation)n - For pressure equipment: For projects within the EU, Category and Module shall be according to PED (Pressure equipment directive)n - Include bolt tension requirements for pressure equipment flangesn - identification of lubrication pointsnnFoundation information (such as support frame, support structure) shall include:n - The outer dimensions and footprint of the support frame or foundation supportsn - The size, grade and location of the foundation bolts and torque where this is necessaryn - Forces and moments transferred to load bearing structures, both under normal operation and extreme conditionsn - Details for adjustment and alignmentn - Details for cut-outs inside outer limit of foundationn - Details for vibration dampening units (if installed)
skos:broadMatch construction entity information
skos:broader Arrangement Drawing

ConstraintsThis section lists constraints that members of 'PCA_100006240' shall satisfy.

ContextThis section provides super- and subtypes as well as members of 'PCA_100006240'.