Helideck drawings (offshore)
A class with identifier
http://rds.posccaesar.org/ontology/plm/rdl/PCA_100006251
MetadataThis section provides information about 'PCA_100006251' itself.
Source ontology | norsok-z001 |
Comment | The following drawings shall be provided:nn1. Entire installation, profile view - all four quadrantsnnThe drawings shall be prepared in accordance with the following requirements:n - Showing entire structure from sea level to highest point;n - Indication of sea level;n - Elevation of helideck above sea level;n - Elevation of highest point above sea level;n - Location of obstacle lights;n - Location of turbine exhaust outlet(s);n - Location of cold emission source(s);n - Location of anemometer(s);n - Scales indicating metres and feet.nnn2. Entire installation, plan view (looking from above)nnThe drawings shall be prepared in accordance with the following requirements:n - Reference to platform and true north;n - Location of obstacle lights;n - Location of turbine exhaust outlet(s);n - Location of cold emission source(s);n - Location of anemometer(s);n - Location of windsock(s);n - Scales indicating metres and feet.nnn3. Helideck with surroundings (can included as a part of 2.)nnThe drawings shall be prepared in accordance with the following requirements:n - Reference to platform and true north;n - Latitude/Longitude (WGS84) of centre helideck;n - Helideck magnetic direction, degrees True;n - Helideck marking;n - Helideck lighting;n - Helideck firefighting equipment;n - HTCC;n - Antenna tower;n - Lowered walkway/Perimeter net;n - Accesses;n - Depiction of Obstacle Free Sectors (180 and 210 degree);n - Depiction of Limited Obstacle Sector (150 degree), including the extent of segment 1 and 2;n - Elevation of structures in 150 LOS segment 1 and 2;n - Elevation of structures close to 210 degree OFS;n - Helicopter fuelling plant;n - Scales indicating metres and feet. |
NORSOK Z-001 rationale | As required in FOR-2007-10-26-1181: |
NORSOK Z-001 interests stakeholder category | environmental |
health | |
safety | |
NORSOK Z-001 describes structural element | Location |
NORSOK Z-001 definition | The following drawings shall be provided:nn1. Entire installation, profile view - all four quadrantsnnThe drawings shall be prepared in accordance with the following requirements:n - Showing entire structure from sea level to highest point;n - Indication of sea level;n - Elevation of helideck above sea level;n - Elevation of highest point above sea level;n - Location of obstacle lights;n - Location of turbine exhaust outlet(s);n - Location of cold emission source(s);n - Location of anemometer(s);n - Scales indicating metres and feet.nnn2. Entire installation, plan view (looking from above)nnThe drawings shall be prepared in accordance with the following requirements:n - Reference to platform and true north;n - Location of obstacle lights;n - Location of turbine exhaust outlet(s);n - Location of cold emission source(s);n - Location of anemometer(s);n - Location of windsock(s);n - Scales indicating metres and feet.nnn3. Helideck with surroundings (can included as a part of 2.)nnThe drawings shall be prepared in accordance with the following requirements:n - Reference to platform and true north;n - Latitude/Longitude (WGS84) of centre helideck;n - Helideck magnetic direction, degrees True;n - Helideck marking;n - Helideck lighting;n - Helideck firefighting equipment;n - HTCC;n - Antenna tower;n - Lowered walkway/Perimeter net;n - Accesses;n - Depiction of Obstacle Free Sectors (180 and 210 degree);n - Depiction of Limited Obstacle Sector (150 degree), including the extent of segment 1 and 2;n - Elevation of structures in 150 LOS segment 1 and 2;n - Elevation of structures close to 210 degree OFS;n - Helicopter fuelling plant;n - Scales indicating metres and feet. |
skos:broadMatch | construction entity information |
geometrical outline information | |
geometrical detail information | |
manufacturing information | |
assembly information | |
skos:broader | Drawing |